Browse through our resource center for more information
Whether you would like to download product selection guides, brochures, product datasheets, installation instructions, CAD drawings, they are all available here.
If you cannot find the resources you need, please feel free to contact us at support@irtec.com or leave a message in our contact us page.
As a professional manufacturer in occupancy sensors for sustainable building control solutions, we strive to develop innovative products that not only allow you to provide occupancy sensing based building control, but also offer versatile selections for OEM lighting fixture integration. We strive to deliver maximum energy savings through simple and effective sensor controls.
The best controls are the ones you don't even realize are there at all.
Occuapancy/Vacancy Sensor
DALI/DALI-2 0-10V On-off ZHAGA BMS/BA Modbus HVAC/Fan Programmer| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
MRD-600SA SmartDALI Occupancy Sensor |
230-240 VAC DALI bus power |
PIR | DALI broadcast | Remote (IR) | Fixture attached | Lead wire | Changeable | UKCA, CE |
![]() |
MRD-510SF MRD-510SW SmartDALI Occupancy Sensor |
230-240 VAC DALI bus power |
PIR | DALI broadcast | Remote (IR) | Changeable, fixture or ceiling | Terminal block | Changeable | UKCA, CE |
![]() |
MRD-210S SmartDALI Occupancy Sensor |
230-240 VAC DALI bus power |
PIR | DALI broadcast | Remote (IR) | Fixture integrated | Terminal block | Fixed | UKCA, CE |
![]() |
MRD-200SP SmartDALI Occupancy Sensor |
230-240 VAC DALI bus power |
PIR | DALI broadcast | Remote (IR) | Batten mount | Lead wire | Fixed | UKCA, CE |
![]() |
MRD-124S MRD-124W SmartDALI Sensor |
DALI bus power | PIR | DALI broadcast | Remote (IR) | Fixture or ceiling | RJ-45 | Fixed | UKCA, CE |
![]() |
MOD-510SF MOD-510SW DALI Occupancy Sensor |
230-240 VAC DALI bus power |
PIR | DALI broadcast | Manual | Changeable, fixture or ceiling | Terminal block | Changeable | UKCA, CE |
![]() |
MRA-514SF MRA-514SW DALI‑2 Occupancy & Light Sensor |
DALI bus power | PIR | DALI-2 | Network | Changeable, fixture or ceiling | Terminal block | Changeable | UKCA, CE |
![]() |
MRA-124S MRA-124W DALI‑2 Occupancy & Light Sensor |
DALI bus power | PIR | DALI-2 | Network | Fixture or ceiling | Plug | Fixed | UKCA, CE |
| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
HRD-600SP SmartDIM Occupancy Sensor |
347/480 VAC | PIR | Switched line voltage 0-10V |
Remote (IR) | Batten mount | Lead wire | Changeable | uL, CA24 |
![]() |
LBD-509SF LBD-509SW SmartDIM Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage (hybrid) 0-10V |
APP (Bluetooth) | Changeable, fixture or ceiling | Lead wire | Changeable | uL, UKCA, CE, FCC, CA24 |
![]() |
LRD-609SA SmartDIM Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage (hybrid) 0-10V |
Remote (IR) | Fixture attached | Lead wire | Changeable | uL, UKCA, CE, CA24 |
![]() |
LRD-509SF LRD-509SW SmartDIM Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage (hybrid) 0-10V |
Remote (IR) | Changeable, fixture or ceiling | Lead wire | Changeable | uL, UKCA, CE, CA24 |
![]() |
LRD-309S SmartDIM Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage (hybrid) 0-10V |
Remote (IR) | Fixture integrated | Lead wire | Changeable | uL, CA24 |
![]() |
LRD-309SP SmartDIM Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage (hybrid) 0-10V |
Remote (IR) | Batten mount | Lead wire | Changeable | uL, CA24 |
![]() |
LMD-509SF Occupancy Sensor |
120-277 VAC | HFD | Switched line voltage (hybrid) 0-10V |
Manual | Changeable, fixture or ceiling | Lead wire | Fixed | uL, UKCA, CE, FCC, CA24 |
![]() |
LMD-109 Occupancy Sensor |
120-277 VAC | HFD | Switched line voltage (hybrid) 0-10V |
Manual | Fixture internal | Lead wire | Fixed | uL, UKCA, CE, FCC, CA24 |
![]() |
BBD-500SF BBD-500SW SmartDIM Occupancy Sensor |
12-24 VDC | PIR | Isolated dry contact 0-10V |
APP (bluetooth) | Changeable, fixture or ceiling | Lead wire | Changeable | UKCA, CE, FCC, CA24 |
![]() |
BBD-510SF BBD-510SW SmartDIM Occupancy Sensor |
12-24 VDC | PIR | Isolated dry contact 0-10V |
APP (bluetooth) | Changeable, fixture or ceiling | Terminal block | Changeable | UKCA, CE, FCC, CA24 |
![]() |
BRD-500SF BRD-500SW SmartDIM Occupancy Sensor |
12-24 VDC | PIR | Isolated dry contact 0-10V |
Remote (IR) | Changeable, fixture or ceiling | Lead wire | Changeable | uL, UKCA, CE, CA24 |
![]() |
BRD-510SF BRD-510SW SmartDIM Occupancy Sensor |
12-24 VDC | PIR | Isolated dry contact 0-10V |
Remote (IR) | Changeable, fixture or ceiling | Terminal block | Changeable | uL, UKCA, CE, CA24 |
![]() |
BOA-516SF BOA-516SW Bi‑Level Occupancy Sensor |
12-24 VDC | PIR | 0-10V | Manual | Changeable, fixture or ceiling | Terminal block | Changeable | uL, UKCA, CE, CA24 |
| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
LRS-509SF LRS-509SW Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage (hybrid) | Remote (IR) | Changeable, fixture or ceiling | Lead wire | Changeable | uL, UKCA, CE, CA24 |
![]() |
LRS-202SP Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage | Remote (IR) | Batten mount | Lead wire | Fixed | UKCA, CE |
![]() |
LOS-509SF LOS-509SW Occupancy Sensor |
120-277 VAC | PIR | Switched line voltage (hybrid) | Manual | Changeable, fixture or ceiling | Lead wire | Changeable | uL, UKCA, CE, CA24 |
![]() |
LOS-505SF LOS-505SW Occupancy Sensor |
120-277 VAC | PIR | Isolated dry contact | Manual | Changeable, fixture or ceiling | Lead wire | Changeable | uL, CE, CA24 |
![]() |
LC-360HI PIR SenSwitch |
100-250 VAC | PIR | Switched line voltage (hybrid) | Manual | Ceiling surface | Lead wire | Fixed | CE |
![]() |
LC-366 PIR SenSwitch |
277 VAC | PIR | Switched line voltage | Manual | Fixture integrated | Terminal block | Fixed | RU |
![]() |
LMS-509SF Occupancy Sensor |
120-277 VAC | HFD | Switched line voltage (hybrid) | Manual | Changeable, fixture or ceiling | Lead wire | Fixed | uL, UKCA, CE, FCC, CA24 |
![]() |
LMS-109 Occupancy Sensor |
120-277 VAC | HFD | Switched line voltage (hybrid) | Manual | Fixture internal | Lead wire | Fixed | uL, UKCA, CE, FCC, CA24 |
![]() |
LVS-508NF LVS-508NW Vacancy Sensor |
220-240 VAC | PIR | Switched line voltage (hybrid) | Manual | Changeable, fixture or ceiling | Lead wire | Changeable | UKCA, CE |
| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
MRD-734SZ SmartDALI Occupancy Sensor |
AUX (+24V) DALI bus power |
PIR | DALI broadcast | Remote (IR) | ZHAGA book 18 | ZHAGA book 18 (type b) | Changeable | UKCA, CE |
| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
COS-516SF COS-516SW LED Control Occupancy Sensor |
12-48 VDC | PIR | PWM | Manual | Changeable, fixture or ceiling | Terminal block | Changeable | uL, UKCA, CE, CA24 |
![]() |
POH-946MEW Under Cabinet Occupancy Sensor |
12-48 VDC | PIR | PWM | None | Under cabinet | Lead wire | Fixed | uL, CE, CA24 |
| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
BOS-515SF BOS-515SW BOS-515NF BOS-515NW Occupancy Sensor |
12-24 VAC/DC | PIR | Isolated dry contact | Manual | Changeable, fixture or ceiling | Terminal block | Changeable | uL, UKCA, CE, CA24 |
![]() |
BDS-600SS Dual-Tech Occupancy Sensor |
12-24 VDC | PIR+HFD | Isolated dry contact | Manual | Ceiling surface | Lead wire | Changeable | uL, UKCA, CE, FCC, CA24 |
![]() |
BDS-610SS Dual-Tech Occupancy Sensor |
12-24 VDC | PIR+HFD | Isolated dry contact | Manual | Ceiling surface | Terminal block | Changeable | uL, UKCA, CE, FCC, CA24 |
| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
MRB-510SF MRB-510SW Occupancy & Daylight Sensor |
12-24 VDC | PIR | Modbus | Network | Changeable, fixture or ceiling | Terminal block | Changeable | UKCA, CE |
| Model | Power | Sensing Tech | Output | Setting | Mount | Connection | Coverage | Compliance | |
![]() |
OS-363 Occupancy Sensor |
24 VAC/DC | PIR | Form C dry contact | Manual | Ceiling surface,recess | Terminal block | Fixed | CE |
![]() |
OS-550 Occupancy Sensor |
24 VAC/DC | PIR | Form C dry contact | Manual | Wall, ceiling, or corner | Terminal block | Fixed | CE |
![]() |
OS-361DT Dual-Tech Occupancy Sensor |
24 VDC | PIR+HFD | Form A dry contact | Manual | Ceiling surface, recess | Terminal block | Fixed | CE, FCC, CA24 |
We use cookies to enhance your browsing experience on our website. By clicking "Accept", you consent to our use of cookies. Cookie Notice
2016-2025 Copyright © IR-TEC International Ltd. All rights reserved.
Privacy Policy | Terms of Use | Disclaimer | Cookie Notice
